Show simple item record

dc.contributor.advisorKassaliete, Evitaen_US
dc.contributor.authorBlāķe, Justīneen_US
dc.contributor.otherLatvijas Universitāte. Fizikas un matemātikas fakultāteen_US
dc.date.accessioned2015-03-24T07:07:04Z
dc.date.available2015-03-24T07:07:04Z
dc.date.issued2012en_US
dc.identifier.other38920en_US
dc.identifier.urihttps://dspace.lu.lv/dspace/handle/7/17720
dc.description.abstractBakalaura darbs uzrakstīts latviešu valodā, datorsalikumā uz 38 lappusēm. Tas satur 12 attēlus, 5 tabulas un 28 atsauces uz literatūras avotiem. Mūsdienās optometrijā arvien vairāk tiek pielietotas dažādas jaunas tehnoloģijas, to skaitā arī datorizēti redzes funkciju izvērtēšanas testi. Šajā darbā aplūkota datorizēta akomodācijas viegluma noteikšanas metode, kurā ar sarkano uz zaļo gaismas filtru palīdzību stimuli katrai acij tiek atdalīti. Darba mērķis: Aprobēt jaunu akomodācijas viegluma testu. Metode: Akomodācijas vieglums tika noteikts 126 eksperimenta dalībniekiem, izmantojot ±2 D lēcu testu un metodi ar krāsu filtriem. Rezultāti: Iegūtie rezultāti ar 95% ticamību tika atzīti par statistiski atšķirīgiem, tāpēc abiem testiem nevar pielietot vienādas normas. Metode ar krāsu filtriem uzrādīja vidēji par vienu ciklu/min zemāku rezultātu nekā standarta metode. Jaunā testa specifika (specificity) ir 87.96% un jutība (sensitivity) ir 72.22%. Atslēgas vārdi: Akomodācijas vieglums, redzes skrīnings, ±2 D lēcu tests, metode ar krāsu filtriem.en_US
dc.description.abstractThe Bachelor Thesis „Approbation of new accommodative facility test” is written in Latvian, contains 38 pages, 12 figures, 5 tables and 28 references to other works. Nowadays a variety of new technologies are applied in optometry, including computerized vision tests. This paper describes new computerized accommodative facility test. The stimulus of this test is separate for each eye using red and green colour filters. Aim: To approbate new accommodative facility test. Method: Accommodative facility was tested with ±2 D test and method with colour filters. Results: Both test results with 95% confidence level are statistically different therefore the same norms cannot be use. The new test with colour filters showed one cycle per minute lower results than the standard method. The specificity of new accommodative facility test is 87.96% but sensitivity is 72.22%. Key words: Accommodative facility, vision screening, ±2 D test, method with colour filters.en_US
dc.language.isoN/Aen_US
dc.publisherLatvijas Universitāteen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectFizikaen_US
dc.titleJauna akomodācijas viegluma testa aprobācijaen_US
dc.title.alternativeApprobation of new accommodative facility testen_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record