dc.description.abstractIzelpotā slāpekļa oksīda līmeņa mērījumi tiek izmantoti kā neinvazīva metode iekaisuma procesu diagnosticēšanai. Mūsu pētījuma mērķis bija novērtēt izelpotā slāpekļa oksīda līmeni akūtas eksogēnas hipoksijas laikā 18 nesmēķējošiem veseliem vīriešiem, kuri nekad nav slimojuši ar kādu hronisku plaušu vai elpošanas sistēmas saslimšanu. Mērķa realizācijai tika izveidota hermētiski noslēgta telpa, kurā tika imitēts atmosfēras gaiss ar skābekļa koncentrāciju atbilstoši 3200m/vjl. Pētījumā tika izmantots hipoksikātors AltiPro 8850 Summit+, kas tandēmā ar necaurlaidīgu, hermētiski noslēgtu telti, radīja eksogēnu hipoksiju pētījuma dalībniekiem. Slāpekļa oksīda līmeņa noteikšanai tika izmantota ierīce Noix Mino (Aerocrine). Pētījuma rezultāti liecina, ka hemoglobīna piesātinājums ar skābekli un izelpotā slāpekļa oksīda līmenis atšķiras pirms hipoksijas un hipoksijas laikā. Pētījumā tika mērīta arī izelpas temperatūra, lai gan pierādījās, ka tā būtiski neatšķiras pirms un pēc hipoksijas.en_US
dc.description.abstractThe measures of amount of nitric oxide in exhaled air is used as a non - invasive method for diagnostics of inflammation. The goal of this survey was to analyse the amount of nitric oxide exhaled from 18 non - smoker, healthy men, when exposed to acute exogen hypoxy. To make the appropriate climate, a hermetically closed room was made and air with a concentration of oxygen according to 3200 meters above sea level was produced. In this study we used hypoxicator AltiPro 8850 Summit+ which together with air-impenetrable, hermetically closed tent, made an exogen hypoxy for the participants. For determination of nitric oxide we used device Noix Mino (Aerocrine). The results of the survey suggest that the amount of hemoglobin and nitric oxide in exhaled air is different before hypoxia and during hypoxia. The measures of temperature of exhaled air were also taken, no changes were found between before and after hypoxia,however.en_US
dc.language.isoN/Aen_US
dc.publisherLatvijas Universitāteen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectFarmācijaen_US
dc.titleIzelpotā slāpekļa oksīda līmenis akūtas eksogēnas hipoksijas apstākļosen_US
dc.title.alternativeThe level of nitric oxide in exhaled air, when exposed to acute exogen hypoxiaen_US
dc.typeinfo:eu-repo/semantics/masterThesisen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record