Показать сокращенную информацию

dc.contributor.advisorFridrihsons, Jānisen_US
dc.contributor.authorVlasenko, Viktorijaen_US
dc.contributor.otherLatvijas Universitāte. Fizikas un matemātikas fakultāteen_US
dc.date.accessioned2015-03-24T06:42:53Z
dc.date.available2015-03-24T06:42:53Z
dc.date.issued2011en_US
dc.identifier.other18595en_US
dc.identifier.urihttps://dspace.lu.lv/dspace/handle/7/16192
dc.description.abstractMaģistra darbs ir uzrakstīts latviešu valodā, datorsalikumā uz 65 lappusēm. Tas satur 38 attēlus, 25 atsauces uz literatūras avotiem. Atslēgas vārdi: Optiskā koherentā tomogrāfija, tīklenes slāņu biezums, perimetrija, redzes lauks, glaukoma Darba mērķis: Salīdzināt optiskās koherentās tomogrāfijas datus ar perimetrijas mērījumiem indivīdiem ar un bez redzeslauka defektiem. Metodika: Tika apstrādāti 9 pētījuma dalībnieku OCT un perimetrijas dati - kontroles; ar glaukomu un ar redzes lauka izmaiņām; ar glaukomu un bez redzes lauka izmaiņām; ar aizdomām uz glaukomu. Tika veikta OCT attēlu apstrāde un manuālā segmentācija, atzīmējot trīs tīklenes slāņus – RNFL, GCL un IPL. Katra indivīda izrēķinātas tīklenes biezuma starpības noteiktajos apgabalos, ņemot vērā kontroles grupas vidēja biezuma vērtības, tika salīdzinātas ar perimetrijas redzes lauka jutības deviācijām. Izrēķinot tīklenes biezuma summas vienā horizontālā meridiānā ietvaros, tika noteikta abu acu tīklenes biezuma simetrija katram indivīdam. Rezultāti: Netika novērota perimetrijas un OCT rādītāju korelācija. Indivīdiem ar glaukomu un redzes lauka defektu var novērot izmaiņas tīklenes slāņu biezumos makulas rajonā. Vislielākā tendence uz biezuma samazinājumu tiek novērota tīklenes nervu šķiedru slānī. Ka arī viņiem var novērot abu acu tīklenes biezuma asimetriju. Indivīdiem ar glaukomu un bez redzes lauka defekta netika noteikts tīklenes biezuma samazinājums kādā no tīklenes slāņiem. Pastāv noteiktas slāņu biezuma svārstības, kuras var novērot arī kontroles grupai. Viņiem tiek novērota cieša korelācija starp abu acu tīklenes biezumiem. Secinājumi: 1) Nevienā no tīklenes ganglionāro šūnu kompleksa slāņiem makulas rajonā netika novērota korelācija starp tīklenes biezuma izmaiņām un redzes lauka jutības izmaiņām. 2) Acīs ar glaukomas diagnozi un ar redzes lauka defektu var novērot tīklenes biezuma samazinājumu nervu šķiedru slānī. 3) Nav iespējams noteikt apgabalus ar lokālu tīklenes slāņu biezuma samazinājumu makulas rajonā indivīdiem ar glaukomu un bez redzes lauka defektiem tā dēļ, ka viņu OCT rezultāti pārklājas ar kontroles indivīdu rezultātiem. 4) Indivīdiem ar glaukomu un redzes lauka defektu var tikt novērota nozīmīga abu acu tīklenes biezuma atšķirība makulas rajonā. 5) Kontroles indivīdiem un indivīdiem ar glaukomu un bez redzes lauka defekta var novērot ciešu abu acu tīklenes slāņu biezumu korelāciju.en_US
dc.description.abstractMaster thesis is written on 65 pages by computer in Latvian. It contains 38 figures. There are 25 references to literature. Key words: optical coherence tomography, retinal layer thickness, perimetry, visual field, glaucoma Aim: To compare optical coherence tomography data with perimetry measurements for subjects with and without visual fields defects. Methods: Data from OCT and perimetry of 9 subjects were analysed – controls; with glaucoma and visual field defects; with glaucoma and without visual field defects; glaucoma suspect. Macular OCT images were processed and manual segmentation was done, three retinal layers were marked – RNFL, GCL and IPL. Retinal thickness differences of macular area were calculated and were compared with perimetry data about visual field sensitivity deviations. Also retinal thickness volume among one horizontal meridian for each patient was calculated to compare the symmetry among both eyes thicknesses for each individual. Results: There is no correlation between perimetry and OCT data. In glaucoma subjects, who had visual field defects, retinal layer thickness changes were found in macular area. The greater thickness decrease tendency was found in retinal nerve fibre layer. Also we could observe retinal thickness asymmetry between two eyes of one subject. In glaucoma subject, who hadn’t have visual field defects, retinal thickness decrease wasn’t found in any of retinal layers. There are definite thickness fluctuations which could be seen also in control subjects and also there is close correlation between the retinal thicknesses of both eyes. Conclusions: 1) There is no correlation between retinal layers thickness and visual field sensitivity in any of retinal layers. 2) Retinal thickness decrease in retinal nerve fibre layer was found in the eyes with glaucoma and visual field defects. 3) It’s not possible to detect areas with localized retinal layer thickness decrease in macular area in subjects who had glaucoma and no visual field defects, because their OCT results were overlapping with results of the control subjects. 4) For subjects, who had glaucoma and visual field defects, significant difference can be found in retinal thicknesses between two eyes. 5) In control subjects and subjects, who had glaucoma but no visual field defects, close correlation of the retinal layer thicknesses can be found between two eyes.en_US
dc.language.isoN/Aen_US
dc.publisherLatvijas Universitāteen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectFizikaen_US
dc.titleOptiskās koherentās tomogrāfijas un perimetrijas rādītāju korelācijaen_US
dc.title.alternativeOptical coherent tomography and perimetry data correlationen_US
dc.typeinfo:eu-repo/semantics/masterThesisen_US


Файлы в этом документе

Thumbnail

Данный элемент включен в следующие коллекции

Показать сокращенную информацию