• English
    • Latviešu
    • Deutsch
    • русский
  • Help
  • English 
    • English
    • Latviešu
    • Deutsch
    • русский
  • Login
View Item 
  •   DSpace Home
  • B4 – LU fakultātes / Faculties of the UL
  • B --- Bij. Fizikas, matemātikas un optometrijas fakultātes studentu noslēguma darbi / Faculty of Physics, Mathematics and Optometry - Graduate works
  • Bakalaura un maģistra darbi (FMOF) / Bachelor's and Master's theses
  • View Item
  •   DSpace Home
  • B4 – LU fakultātes / Faculties of the UL
  • B --- Bij. Fizikas, matemātikas un optometrijas fakultātes studentu noslēguma darbi / Faculty of Physics, Mathematics and Optometry - Graduate works
  • Bakalaura un maģistra darbi (FMOF) / Bachelor's and Master's theses
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Jauna datorizēta stereoredzes kvalitātes noteikšanas testa aprobācija redzes skrīningam

Thumbnail
View/Open
304-34019-Jukse_Zane_zj08005.pdf (1.325Mb)
Author
Jukse, Zane
Co-author
Latvijas Universitāte. Fizikas un matemātikas fakultāte
Advisor
Krūmiņa, Gunta
Date
2013
Metadata
Show full item record
Abstract
Maģistra darbs ir uzrakstīts latviešu valodā uz 58 lappusēm. Tas satur 32 attēlus, 11 tabulas un 33 atsauces uz literatūras avotiem. Mērķis: Izstrādāt datorizētu stereoredzes kvalitātes noteikšanas testu redzes skrīningam. Dalībnieki un metodika: Pētījumā piedalījās 709 skolēni vecumā 6-19 gadi. Stereoredzes kvalitāte tika noteikta ar TNO testu un jauno datorizēto ON stereotestu. Abi testi ir veidoti pēc anaglifa un izkliedēto punktu metodes. Rezultāti: 1.TNO testā skolēnu vidējais stereoredzes asums ir 100”±73”, bet ON testā – 135”±103”. 2.Abos stereoredzes testos novērojama līdzīga tendence – pieaugot skolēnu vecumam, stereoredzes kvalitāte pasliktinās. 3.Jaunā datorizētā ON testa noteiktā robežvērtība ir 154”, turpretim jutība ir 48%, bet specifiskums – 85%. Atslēgvārdi: stereoredze, stereoredzes kvalitāte, anaglifa metode, TNO tests
 
Master’s thesis is written on 58 pages in Latvian. It contains 32 pictures, 11 tables and 33 references to literature. Purpose: To develop computerized test for stereovision quality evaluation for vision screening. Subjects and methods: 709 pupils between 6 and 19 years take part in stereovision screening. Screening was performed using TNO test and a new computerized ON stereovison test. Both tests use an anaglyphic technique and random-dot patterns. Results: 1.The mean stereopsis with TNO test in school children was 100±73 arc seconds, but with ON test – 135±103 arc seconds. 2.A similar trend was observed in both stereovision tests – stereovision quality deteriorates with increasing children age. 3.The cut-off point of computerized ON test is 154 arc seconds, while tests sensitivity is 48% and specificity 85%. Key words: stereovision, stereovision quality, anaglyph method, TNO test
 
URI
https://dspace.lu.lv/dspace/handle/7/16245
Collections
  • Bakalaura un maģistra darbi (FMOF) / Bachelor's and Master's theses [2775]

University of Latvia
Contact Us | Send Feedback
Theme by 
@mire NV
 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

View Usage Statistics

University of Latvia
Contact Us | Send Feedback
Theme by 
@mire NV