Zur Kurzanzeige

dc.contributor.advisorSkudra, Atisen_US
dc.contributor.authorFjodorovs, Viktorsen_US
dc.contributor.otherLatvijas Universitāte. Fizikas un matemātikas fakultāteen_US
dc.date.accessioned2015-03-24T08:01:34Z
dc.date.available2015-03-24T08:01:34Z
dc.date.issued2013en_US
dc.identifier.other33943en_US
dc.identifier.urihttps://dspace.lu.lv/dspace/handle/7/21704
dc.description.abstractDarba gaitā ar speciālās infrasarkanās kameras un iepriekš izstrādātās termoregulācijas sistēmas palīdzību tika precizēts temperatūras diapazons, kurā augstfrekvences bezelektrodu lampas aukstākais punkts paliek kontaktā ar termostatu. Tika veikti vairāki uzlabojumi paštaisītai termoregulācijas iekārtai, kas paredzēta augstfrekvences bezelektrodu lampu (ABL) emisijas spektra pētījumiem atkarībā no ABL aukstākā punkta temperatūras. Ņemot vērā precizēto temperatūras diapazonu, tika izmainīts spektru uzņemšanas algoritms, kas padarīja procesu vieglāku, ātrāku, bet pašus mērījumus precīzākus. Pēc padarītajiem uzlabojumiem tika uzņemti emisijas spektri 6 dažādām ABL, kuras pildītas ar Hg un inertās gāzes maisījumu. Tika konstatēts, ka, pieaugot temperatūrai, emisijas intensitāte lampām mainas ar dažādu ātrumu. Lampām ar lielāku inertās gāzes spiedienu, vai ar smagāku inerto gāzi, 184.9 nm dzīvsudraba rezonanses līnijas intensitātes izmaiņa ir lēnāka un izskatās lineārāka.en_US
dc.description.abstractDuring this work, using special infrared camera and previously developed thermoregulation system the correct experimental temperature range has been determined, where the “cold spot” of high frequency electrodeless lamp (HFEDL) remains in contact with thermostat. Several improvements have been made to the self-developed thermoregulating system, which can be used for HFEDL emission spectra investigation depending on “cold spot” temperature. According to the adjusted experimental temperature range the algorithm of spectra registration has been modified, so the process of data accumulation became faster and simpler, and the accuracy of mesuraments was increased. The emission spectra of 6 different HFEDLs with Hg and inert gas mixture were obtained after the improvements have been made. It was found that by increasing the cold spot temperature the emission intensity increases. For lamps with higher inert gas pressure or a heavier inert gas the 184.9 nm mercury resonance line intensity changes are slower and look more linear.en_US
dc.language.isoN/Aen_US
dc.publisherLatvijas Universitāteen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectFizikaen_US
dc.titleDzīvsudrabu saturošu augstfrekvences bezelektrodu lampu spektroskopiskie mērījumien_US
dc.title.alternativeSpectroscopic measurements of Mercury-containing high-frequency electrodeless lampsen_US
dc.typeinfo:eu-repo/semantics/masterThesisen_US


Dateien zu dieser Ressource

Thumbnail

Das Dokument erscheint in:

Zur Kurzanzeige