Tritija termodesorbcija no plazmas kamerā izmantotiem oglekļa šķiedras kompozīt materiāliem

Thumbnail
Öffnen
300-48803-Conka_Davis_dc12011.pdf (1.389Mb)
Autor
Čonka, Dāvis
Co-author
Latvijas Universitāte. Ķīmijas fakultāte
Advisor
Vītiņš, Aigars
Datum
2015
Metadata
Zur Langanzeige
Zusammenfassung
Darbā pētīta tritija termodifūzija no kodolsintēzes iekārtas Apvienotais Eiropas tors (Joint European Torus - JET) divu darbības kampaņu periodiem (2007-2009 un 2010-2012) ar atšķirīgu pirmās sienas konstrukciju. Tritija termodifūzija veikta plazmas skartiem vienādās divertora pozīcijās esošiem ar volframu nepārklātiem un pārklātiem ķieģeļiem un 2010. gadā savāktam vakuuma kameras putekļu un plēkšņu maisījumam. Tritija maksimālais izdalīšanās ātrums no oglekļa C-sienas konstrukcijas divertora ķieģeļiem bez volframa pārklājuma (2007-2009. gada kampaņa) ir ap 730 K. 2010.-2012. gada kampaņas ar volframu pārklātajam jeb ILW-paraugam tritija izdalīšanās maksimuma temperatūra tiek sasniegta ātrāk nekā C-sienas paraugam. ILW-paraugam tritija izdalīšanās maksimums iestājās ap 690 K, bet C-sienas paraugam tritija izdalīšanās maksimums iestājas par 40 K augstākā temperatūrā. 2010. gadā savāktajiem putekļiem tritija termodesorbcijas spektrā ir 2 tritija izdalīšanās maksimumi. Pirmais maksimums, 150 Bq/(s*g), ir ~500 K temperatūrā, bet otrais maksimums, 410 Bq/(s*g), ir 997 K temperatūrā.
 
Tritium thermodesorption was studied for samples of the fusion reactor Joint European Torus (JET) with different first wall constructions for two operational periods: experimental campaigns in period 2007-2009 and 2010-2012, accordingly. Analysis was performed for plasma facing samples from tiles at equal divertor positions with tungsten uncoated and coated tiles and for dust material, consisting from dust and flakes, collected from JET vacuum chamber in year 2010 Tritium release maximum rate of carbon C-wall divertor tile sample without tungsten coating (2007-2009) is around 730 K. For the tungten coated sample from operationlal period 2010-2012 (ILW-sample) tritium release peak temperature is reached faster than in case of C-wall sample. In thermodesorption profile of ILW-sample tritium release maximum occurred around 690 K, while for C-wall sample maximum tritium release occurs at about 40 K higher temperature. Tritium thermodesorption spectrum for dust and flakes mixture collected in 2010 has 2 tritium release maxima. The first maximum of 150 Bq / (g * s) is ~500 K while the second of 410 Bq / (g * s) is at 997 K temperature.
 
URI
https://dspace.lu.lv/dspace/handle/7/30225
Collections
  • Bakalaura un maģistra darbi (ĶF) / Bachelor's and Master's theses [1583]

University of Latvia
Kontakt | Feedback abschicken
Theme by 
@mire NV
 

 

Stöbern

Gesamter BestandBereiche & SammlungenErscheinungsdatumAutorenTitelnSchlagwortenDiese SammlungErscheinungsdatumAutorenTitelnSchlagworten

Mein Benutzerkonto

Einloggen

Statistik

Benutzungsstatistik

University of Latvia
Kontakt | Feedback abschicken
Theme by 
@mire NV