Показать сокращенную информацию

dc.contributor.authorParis, B.
dc.contributor.authorButikova, Jelena
dc.contributor.authorLaan, M.
dc.contributor.authorHakola, A.
dc.contributor.authorJõgi, I.
dc.contributor.authorLikonen, J.
dc.contributor.authorGrigore, E.
dc.contributor.authorRuset, C.
dc.date.accessioned2020-08-19T17:21:58Z
dc.date.available2020-08-19T17:21:58Z
dc.date.issued2019
dc.identifier.issn2352-1791
dc.identifier.urihttps://dspace.lu.lv/dspace/handle/7/52413
dc.descriptionThis work has been carried out within the framework of the EUROfusion Consortium and has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement number 633053. The views and opinions expressed herein do not necessarily reflect those of the European Commission. Work performed under EUROfusion WP PFC.en_US
dc.description.abstractITER foresees applying laser induced breakdown spectroscopy (LIBS) as a tool for quantitative assessment of fuel retention in the first walls. One open problem related to LIBS application is the choice of the laser type. Here we compare two Nd/YAG lasers with different pulse durations, 0.15 and 8 ns, working at λ = 1064 nm for LIBS studies of samples with D-doped W/Al coatings of ≈ 3 μm thickness (Al is used as a proxy of Be) on Mo. Low pressure argon was used as a background gas. Experiments were done in conditions where other factors (broadening of spectral lines, signal-to-noise ratio, limited thickness of coatings etc.) did not shadow the effect of laser pulse duration. For these reasons, low pressure argon was used as the background gas and fluences were kept at comparatively low values. Spectra of laser-produced plasma were recorded as a function of the number of laser pulses. Partially overlapping lines of hydrogen isotopes were fitted with Voigt contours, intensities were fitted and depth profiles of deuterium were reconstructed. The relative standard error of curve-fitting of spectra recorded with the laser of shorter pulse duration was two times smaller than that recorded by the longer pulse laser. The electron density was found from the Stark broadening of Hα line of the laser-produced plasma and the electron temperature of plasma was found on the basis W and Mo lines. It was found that in the case of ps laser an acceptable accuracy of the detection of deuterium was possible at considerably lower values of fluence. Steps needed for comparison of ps and ns lasers in ITER-relevant conditions were discussed.en_US
dc.description.sponsorshipHorizon 2020 Framework Programme 633053; Institute of Solid State Physics, University of Latvia as the Center of Excellence has received funding from the European Union’s Horizon 2020 Framework Programme H2020-WIDESPREAD-01-2016-2017-TeamingPhase2 under grant agreement No. 739508, project CAMART²en_US
dc.language.isoengen_US
dc.publisherElsevier Ltden_US
dc.relationinfo:eu-repo/grantAgreement/EC/H2020/739508/EU/Centre of Advanced Material Research and Technology Transfer/CAMART²en_US
dc.relation.ispartofseriesNuclear Materials and Energy;18
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectResearch Subject Categories::NATURAL SCIENCES:Physicsen_US
dc.subjectDetection of hydrogen isotopesen_US
dc.subjectElemental depth profilesen_US
dc.subjectITER-relevant coatingsen_US
dc.subjectLIBS diagnosticsen_US
dc.subjectTemperature of laser-produced plasmaen_US
dc.titleComparison of LIBS results on ITER-relevant samples obtained by nanosecond and picosecond lasersen_US
dc.typeinfo:eu-repo/semantics/articleen_US
dc.identifier.doi10.1016/j.nme.2018.11.018


Файлы в этом документе

Thumbnail

Данный элемент включен в следующие коллекции

Показать сокращенную информацию