• English
    • Latviešu
    • Deutsch
    • русский
  • Help
  • Deutsch 
    • English
    • Latviešu
    • Deutsch
    • русский
  • Einloggen
Dokumentanzeige 
  •   DSpace Startseite
  • B4 – LU fakultātes / Faculties of the UL
  • B --- Bij. Fizikas, matemātikas un optometrijas fakultātes studentu noslēguma darbi / Faculty of Physics, Mathematics and Optometry - Graduate works
  • Bakalaura un maģistra darbi (FMOF) / Bachelor's and Master's theses
  • Dokumentanzeige
  •   DSpace Startseite
  • B4 – LU fakultātes / Faculties of the UL
  • B --- Bij. Fizikas, matemātikas un optometrijas fakultātes studentu noslēguma darbi / Faculty of Physics, Mathematics and Optometry - Graduate works
  • Bakalaura un maģistra darbi (FMOF) / Bachelor's and Master's theses
  • Dokumentanzeige
JavaScript is disabled for your browser. Some features of this site may not work without it.

Lēcu virsmas atstarotās gaismas ietekme uz redzes kvalitāti

Thumbnail
Öffnen
304-76060-Rizkova_Natalija_nr18018.pdf (891.7Kb)
Autor
Rižkova, Natālija
Co-author
Latvijas Universitāte. Fizikas, matemātikas un optometrijas fakultāte
Advisor
Ikaunieks, Gatis
Datum
2021
Metadata
Zur Langanzeige
Zusammenfassung
arbs ir uzrakstīts latviešu valodā uz 39 lapaspusēm. Tas satur 13 attēlus, 4 tabulas, 32 atsauces uz literatūras avotiem. Maģistra darba mērķis ir dzidrināto pārklājumu un briļļu lēcu refrakcijas koeficienta ietekmes uz redzes asumu izpēte. Darba mērķa sasniegšanai 20 pacientiem tika piedāvāti redzes asuma pārbaudes testēšanas pētījumi: ar augstā indeksa lēci bez dzidrinātā pārklājuma, ar augstā indeksa lēci ar atstarojošo pārklājumu, ar lēcu ar refrakcijas koeficientu 1.5 un dzidrināto pārklājumu. Pēc darba rezultātiem tika secināts, ka starp rezultātiem, kas saņemti ar lēcu ar pārklājumu izmantošanu, īpašas starpības nav. Tomēr, augstā indeksa lēca bez papildus pārklājuma lielā mērā samazināja eksperimenta dalībnieku redzes asumu.
 
Present work was published in Latvian language, on 39 pages. It contains 13 figures, and 4 tables, 32 of references were used throughout the text. Aim of the current Master's degree project was to demonstrate how lense refractory coefficient and antiglare coating affect visual capacity in humans. Materials and methods: visual capacity of 20 patients was determined using the following equipment: high refractory coefficient lens with antiglare coating, high refractory coefficient lens without antiglare coating, and lens with refractory coefficient of 1.5 and antiglare coating. After considering gathered data it was determined that difference in visual capacity in use of lenses with antiglare coating but different refractory coefficient is negligible. In contrast, data reported on use of non-antiglare coated lenses demonstrated considerable loss of visual capacity in participants.
 
URI
https://dspace.lu.lv/dspace/handle/7/55899
Collections
  • Bakalaura un maģistra darbi (FMOF) / Bachelor's and Master's theses [2775]

University of Latvia
Kontakt | Feedback abschicken
Theme by 
@mire NV
 

 

Stöbern

Gesamter BestandBereiche & SammlungenErscheinungsdatumAutorenTitelnSchlagwortenDiese SammlungErscheinungsdatumAutorenTitelnSchlagworten

Mein Benutzerkonto

Einloggen

Statistik

Benutzungsstatistik

University of Latvia
Kontakt | Feedback abschicken
Theme by 
@mire NV