Dzīvsudrabu un arsēnu saturoši starojuma avoti un to izmantošana atomu absorbcijas spektroskolijai

Thumbnail
Öffnen
298-99769-Abola_Anda_as06120.pdf (103.3Mb)
Autor
Ābola, Anda
Co-author
Latvijas Universitāte. Fizikas, matemātikas un optometrijas fakultāte
Advisor
Rēvalde, Gita
Skudra, Atis
Datum
2024
Metadata
Zur Langanzeige
Zusammenfassung
Promocijas darbā veikti LU ASI izgatavoto arsēna un dzīvsudraba augstfrekvences bezelektrodu lampu spektroskopiskie pētījumi: noteikta rezonanses spektrāllīniju intensitātes atkarība no ierosmes ģeneratora jaudas, frekvences un darbināšanas režīma, novērtēta lampu stabilitāte, pašabsorbcija un temperatūra. Iegūti šādi galvenie secinājumi: getera pievienošana uzlabo lampu darbību, lampu starojuma fluktuācijas nepārsniedz 2% robežu, As lampu temperatūra ir apmēram 950 – 1250 K, pašabsorbcijas dēļ optimāla darbināšanas jauda ir apmēram 14 W, Hg kapilāra lampas ieteicams novietot ar kapilāru horizontāli, sfēriskās Hg lampas ieteicams darbināt E–izlādē, bet As lampas – H–izlādē. Veikti arī praktiski Hg koncentrācijas mērījumi melno stārķu olu čaumalās un fēcēs, un ezera ūdenī, izmantojot atomu absorbcijas spektrometru ar Zēmana fona korekciju.
 
The thesis explores spectroscopic studies of mercury and arsenic high-frequency electrodeless lamps produced by UL IAPS. It examines the dependence of resonance spectral line intensity on generator power, frequency, and operating mode. Lamp stability, self-absorption, and temperature were assessed. Key findings include: getter addition enhances lamp performance, radiation fluctuations stay below 2%, As lamp temperature ranges from 950 – 1250 K, optimal operating power due to self-absorption is around 14 W, it is recommended to place Hg capillary lamps with capillary horizontally, to operate spherical Hg lamps in E-discharge, and As lamps in H-discharge. Practical Hg concentration measurements were also conducted in black stork eggshells and feces, and lake water using an atomic absorption spectrometer with Zeeman background correction.
 
URI
https://dspace.lu.lv/dspace/handle/7/65449
Collections
  • Promocijas darbi (2007-) / Theses PhD [1374]

University of Latvia
Kontakt | Feedback abschicken
Theme by 
@mire NV
 

 

Stöbern

Gesamter BestandBereiche & SammlungenErscheinungsdatumAutorenTitelnSchlagwortenDiese SammlungErscheinungsdatumAutorenTitelnSchlagworten

Mein Benutzerkonto

Einloggen

Statistik

Benutzungsstatistik

University of Latvia
Kontakt | Feedback abschicken
Theme by 
@mire NV