Zema kontrasta redzes asuma testu pielietojums redzes kvalitātes novērtēšanai
| dc.contributor.advisor | Ikaunieks, Gatis | en_US |
| dc.contributor.author | Ansone, Ieva | en_US |
| dc.contributor.other | Latvijas Universitāte. Fizikas un matemātikas fakultāte | en_US |
| dc.date.accessioned | 2015-03-24T08:24:27Z | |
| dc.date.accessioned | 2025-07-20T21:03:51Z | |
| dc.date.available | 2015-03-24T08:24:27Z | |
| dc.date.issued | 2012 | en_US |
| dc.description.abstract | Maģistra darbs ir uzrakstīts latviešu valodā, datorsalikumā uz 46 lappusēm. Tas satur 26 attēlus, 4 tabulas, 41 atsauci uz literatūras avotiem. Mērķis: Novērtēt zema kontrasta redzes asuma testu rezultātu pielietojumu redzes kvalitātes novērtēšanai. Metodika: Ar programmu FrACT tika noteikts augsta un zema kontrasta redzes asums, izmantojot dažādu līmeņu gaismu izkliedējošos filtrus. Rezultāti un secinājumi: Augsta kontrasta redzes asuma (AKRA) tests uzrāda vidēji ciešu korelāciju ar zema kontrasta redzes asuma (ZKRA) testiem (r = 0,7). ZKRA testi ir jutīgāki par AKRA testu paaugstinātas acī „noklīdušās” gaismas gadījumā, tomēr nav izmantojami acī „noklīdušās” gaismas līmeņa novērtēšanai, jo uzrāda individuālās atšķirības starp dalībniekiem. Atslēgvārdi: augsta kontrasta redzes asums, zema kontrasta redzes asums, acī „noklīdusī” gaisma. | en_US |
| dc.description.abstract | Master work is written in Latvian, it contains of 46 printed pages, 26 figures, 4 tabeles and 41 literature sources have been used. Purpose: To asses usefulness of low contrast visual acuity for assesment of visual quality. Methods: With the FrACT program was performed visual test with high and low contrast, using filters with different levels of straylight. Results and conclusions: The high-contrast visual acuity (HCVA) test indicates a modest strong correlation with the low-contrast visual acuity (LCVA) tests (r = 0,7). LCVA tests are more sensitive to increased intraocular straylight, but not be used to asses level of intraocular straylight, because they show individual difference between participants. Keywords: high contrast visual acuity, low contrast visual acuity, intraocular straylight. | en_US |
| dc.identifier.other | 22371 | en_US |
| dc.identifier.uri | https://dspace.lu.lv/handle/7/23664 | |
| dc.language.iso | N/A | en_US |
| dc.publisher | Latvijas Universitāte | en_US |
| dc.rights | info:eu-repo/semantics/openAccess | en_US |
| dc.subject | Fizika | en_US |
| dc.title | Zema kontrasta redzes asuma testu pielietojums redzes kvalitātes novērtēšanai | en_US |
| dc.title.alternative | Assessment of visual quality with low contrast acuity tests | en_US |
| dc.type | info:eu-repo/semantics/masterThesis | en_US |