dc.description.abstractDarba mērķi:Salīdzināt dažāda materiāla elektrodu ietekmi uz audu pretestības mērījumiem, kā arī noskaidrot, vai pastāv korelācija starp audu pretestību un sekojošiem parametriem: frekvenci (diapazonā no 1 kHz līdz 349 kHz), audu temperatūru (no 400C līdz 1000C), attālumu starp elektrodiem (no 2,5 mm līdz 15,0 mm), elektrodu novietojumu audos (1mm, 4mm un 10mm audu dziļumā) un audu bojājuma dziļumu. Secinājumi:Pastāv korelācija (no vājas līdz augstai, atkarībā no audu tipa) starp audu pretestību un frekvenci.Pastāv ļoti liela korelācija starp audu pretestību un temperatūru.Pastāv augsta korelācija starp audu pretestību un elektroda novietojumu audu dziļumā.Pastāv ļoti augsta korelācija starp audu pretestību un attālumu starp elektrodiem.Augstāki audu pretestības iegūti rādītāji, veicot griezienu ar elektroķirurģisko ģeneratoru Surtron Flash 160, histoloģiskajā nieres audu preparātu analīzē uzrādīja plašākas audu bojājuma zonas, salīdzinājumā ar zemākiem pretestības datiem.en_US
dc.description.abstractStudy objective:To compare the effect of different electrodes on tissue impedance measurements and to find out, if there’s correlation between tissue impedance and frequency (at range from 1 kHz to 349 kHz), tissue temperature (from 400C to 1000C), distance between electrodes ( from 2,5 mm to 15,0 mm), electrode insertion depth (1mm, 4mm and 10mm) and depth of tissue damage. Conclusions:There is a correlation between tissue impedance and frequency, also depending on the tissue type. Very high correlation exists between tissue impedance and temperature.Very high correlation exists between impedance and distance between electrodes, which were used to measure tissue impedance.Histological analysis of kidney tissue samples showed larger tissue damage area for tissue with higher impedance, using high frequency electrosurgical unit – Surtron Flash 160, compared to tissue with lower impedance values.en_US
dc.language.isoN/Aen_US
dc.publisherLatvijas Universitāteen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectMedicīnaen_US
dc.titleAudu pretestības mērījumu nozīme intersticiālās radiofrekvenču ķirurģijas novērtēšanāen_US
dc.title.alternativeThe meaning of Tissue Impendance Measurements for the evaluation of interstitial radiogreqvency surgeryen_US
dc.typeinfo:eu-repo/semantics/bachelorThesisen_US