Show simple item record

dc.contributor.advisorFridrihsons, Jānisen_US
dc.contributor.authorBabenko, Jeļenaen_US
dc.contributor.otherLatvijas Universitāte. Fizikas un matemātikas fakultāteen_US
dc.date.accessioned2015-03-24T06:29:21Z
dc.date.available2015-03-24T06:29:21Z
dc.date.issued2007en_US
dc.identifier.other25905en_US
dc.identifier.urihttps://dspace.lu.lv/dspace/handle/7/15191
dc.description.abstractMaģistra darbs uzrakstīts latviešu valodā. Tam ir 46 lappuses. Tas satur 18 attēlus, 8 tabulas, 1 pielikumu un 33 literatūras avotu atsauksmes. Darba mērķis: Salīdzināt astigmātiskas un sfēriskas korekcijas skaidras redzes apgabalus tuvumā presbiopiem pacientiem ar astigmātismu. Pacienti: Eksperimentā laikā tika izmeklēti 55 pacienti presbiopijas vecumā, vidējā vecumā 54.8 gadi, no 40 līdz 78 gadiem. Refrakcijas astigmātiska komponente viņiem bija dažāda no 0.5 D līdz 2.0 D liela astigmātisma. Piedalījās cilvēki ar tieša, apgriezta un slīpa astigmātisma veidiem. Visiem bija noteikta labāka sfēriska korekcija un labāka astigmātiska korekcija gan tālumā, gan tuvumā. Pacientiem tika noteikts un salīdzināts tuvākais skaidras redzes punkts (PP), tālākais skaidras redzes punkts (PR) un skaidras redzes apgabals. Rezultāti un to analīze: PP un PR ar labāku astigmātisku un ar labāku sfērisku korekciju presbiopiem pacientiem būtiski neatšķiras, tie pārklājās kļūdu robežās. Ar labāku astigmātisku korekciju PP=21.222.94 cm, PR=62.453.25 cm un ar labāku sfērisku korekciju PP=21.673.02 cm, PR=62.383.7 cm. No visiem pacientiem tika izdalīti 10 cilvēki, kuriem astigmātiska komponente ir 1.0 D. Šiem pacientiem ir redzama tendence, ka PP un PR ir mazāki pacientiem ar astigmātisku korekciju, kaut šie lielumi arī pārklājas kļūdu robežās. Ar astigmātisku korekciju PP=20.62.76 cm, PR=60.31.77 cm, ar sfērisku korekciju PP=22.23.22 cm, PR=61.32.16 cm. Secinājumi: Iegūtie rezultāti paradīja, ka nelielas pakāpes astigmātiska kļūda neietekmē skaidras redzes apgabalu presbiopiem pacientiem ar astigmātismu. Atslēgvārdi: Presbiopija, astigmātisms, akomodācijas amplitūda.en_US
dc.description.abstractMaster thesis is written in Latvian language. It contains 46 pages, 18 figures, 8 tables, 1 appendix and 33 references. Purpose: To compare astigmatic and spherical corrections values influence on zone of clear vision for presbyopic patients with astigmatisms. Patients: The experiment was performed on 55 presbyopic patients. The mean age was 54.8 years with a range from 40 to 78 years. The refractive error was in a range from 0.5 D to 2.0 D. The patients with against-the-rule, with-the-rule and oblique astigmatism were investigated. The astigmatic and spherical corrections for near and far vision have been found. The near clear vision point (PP), the far clear vision point (PR) and the zone of clear vision have been found and compared between all patients. Results: The PP and PR values obtained with astigmatic and spherical corrections coincide with in the experimental errors. The mean PP and PR values are 21.222.94 cm and 62.453.25 cm correspondingly for astigmatic correction, and 21.673.02 cm and 62.383.7 cm correspondingly for spherical correction. Emphasis was placed on PP and PR for patients with astigmatic correction 1.0 D. The PP and PR values for this group of patients are closer for astigmatic correction than for spherical correction (PP=20.62.76 cm, PR=60.31.77 cm for astigmatic correction and PP=22.23.22 cm, PR=61.32.16 cm for spherical correction). Conclusions: Obtain results shows, that the small astigmatic error doesn’t have influence on zone of clear vision for presbyopic patients with astigmatism. Keywords: Presbyopia, astigmatism, amplitude of accommodationen_US
dc.language.isoN/Aen_US
dc.publisherLatvijas Universitāteen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectFizikaen_US
dc.titleAstigmatiskas korekcijas ietekme uz skaidras redzes apgabalu presbiopiem pacientiemen_US
dc.title.alternativeInfluence of astigmatic correction on zone of clear vision in presbiopic patientsen_US
dc.typeinfo:eu-repo/semantics/masterThesisen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record