Show simple item record

dc.contributor.advisorFridrihsons, Jānisen_US
dc.contributor.authorBriede, Daceen_US
dc.contributor.otherLatvijas Universitāte. Fizikas un matemātikas fakultāteen_US
dc.date.accessioned2015-03-24T07:36:20Z
dc.date.available2015-03-24T07:36:20Z
dc.date.issued2011en_US
dc.identifier.other18447en_US
dc.identifier.urihttps://dspace.lu.lv/dspace/handle/7/19618
dc.description.abstractMaģistra darbs ir uzrakstīts latviešu valodā, datorsalikumā uz 44 lapām. Tas satur 22 attēlus, 2 tabulas, 34 atsauces uz literatūras avotiem. Darba mērķis: Noskaidrot, vai Bagolini testa atrade ir atkarīga no izmantotā gaismas avota lieluma. Metode: Veicot testu kopumu 98 ar optometriju nesaistītiem dalībniekiem, tika novērtēts redzes sistēmas stāvoklis. Dalībnieki tika iedalīti divās grupās: bez redzes sistēmas patoloģijas (64) un ar redzes sistēmas patoloģiju (34). Bagolini tests tika veikts, izmantojot divus dažādus gaismas avotus. Atrade katrā grupā tika salīdzināta, izmantojot Kappas koeficienta vērtību. Papildus veikts Vorsa četu punktu tests un sarkanā stikla tests, lai varētu novērtēt Bagolini testa nozīmi klīnikā. Kā arī tika vērtēta stereoredze ar Titmusa testu, lai noteiktu vai pastāv saistība starp stereoredzes kvalitāti un redzes raksturu. Rezultāti: Visās dalībnieku grupās Kappas koeficienta vērtība ir no 0,659 līdz 1, kas norāda uz vidēji augstu un augstu sakritību starp izmantotajām metodēm. Bagolini testa jutība supresijas atklāšanā ir 76% un specifiskums – 100%. Secinājumi: Bagolini testa atrade nav atkarīga no izmantojamā gaismas avota lieluma. Bagolini tests ir klīnikā nozīmīgs supresijas skotomas novērtēšanas tests. Novērtējot stereoredzes kvalitāti nevar spriest par supresijas skotomas atradi.en_US
dc.description.abstractMaster's thesis is written in Latvian by computer on 44 pages. It contains 22 figures, 2 tables. There are 34 references to the literature. Objective: To determine if Bagolini striated lens test results depend on the size of the target light used. Methods: Using specific test battery for 98 subjects, unfamiliar with optometry, was assessed state of the visual system. Participants were divided into two groups: without visual system abnormalities (64) and with visual system abnormalities (34). Bagolini striated lens test was performed using two different light sources. Results in each group were compared using the Kappa coefficient. In addition was performed the Worth Four Dot test and the red glass test in order to evaluate the role of the Bagolini striated lens test in clinic. It was evaluated stereopsis with Titmuss test to determine the relationship between the quality of stereopsis and binocular vision. Results: In all groups Kappa coefficient value is from 0,659 to 1, indicating a moderately high to high agreement between the methods used. Sensitivity of the Bagolini striated lens testi s 76% and specificity – 100%. Conclusions: The size of the target light used in conjunction with the Bagolini striated lens test has no significant effect on patient response. Bagolini striated lens test is clinically significant for evaluation of suppression scotoma. It is not possible to predict suppression scotoma findings from determining the quality of stereopsis.en_US
dc.language.isoN/Aen_US
dc.publisherLatvijas Universitāteen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectFizikaen_US
dc.titleBagolini testa atrade atkarībā no izmantojamā gaismas avotaen_US
dc.title.alternativeDependence of Bagolini test findings on light sourceen_US
dc.typeinfo:eu-repo/semantics/masterThesisen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record