dc.contributor.advisor | Ikaunieks, Gatis | en_US |
dc.contributor.author | Ansone, Ieva | en_US |
dc.contributor.other | Latvijas Universitāte. Fizikas un matemātikas fakultāte | en_US |
dc.date.accessioned | 2015-03-24T08:24:27Z | |
dc.date.available | 2015-03-24T08:24:27Z | |
dc.date.issued | 2012 | en_US |
dc.identifier.other | 22371 | en_US |
dc.identifier.uri | https://dspace.lu.lv/dspace/handle/7/23664 | |
dc.description.abstract | Maģistra darbs ir uzrakstīts latviešu valodā, datorsalikumā uz 46 lappusēm. Tas satur 26
attēlus, 4 tabulas, 41 atsauci uz literatūras avotiem.
Mērķis: Novērtēt zema kontrasta redzes asuma testu rezultātu pielietojumu redzes
kvalitātes novērtēšanai.
Metodika: Ar programmu FrACT tika noteikts augsta un zema kontrasta redzes asums,
izmantojot dažādu līmeņu gaismu izkliedējošos filtrus.
Rezultāti un secinājumi: Augsta kontrasta redzes asuma (AKRA) tests uzrāda vidēji ciešu
korelāciju ar zema kontrasta redzes asuma (ZKRA) testiem (r = 0,7). ZKRA testi ir jutīgāki par
AKRA testu paaugstinātas acī „noklīdušās” gaismas gadījumā, tomēr nav izmantojami acī
„noklīdušās” gaismas līmeņa novērtēšanai, jo uzrāda individuālās atšķirības starp dalībniekiem.
Atslēgvārdi: augsta kontrasta redzes asums, zema kontrasta redzes asums, acī „noklīdusī”
gaisma. | en_US |
dc.description.abstract | Master work is written in Latvian, it contains of 46 printed pages, 26 figures, 4 tabeles and
41 literature sources have been used.
Purpose: To asses usefulness of low contrast visual acuity for assesment of visual quality.
Methods: With the FrACT program was performed visual test with high and low contrast,
using filters with different levels of straylight.
Results and conclusions: The high-contrast visual acuity (HCVA) test indicates a modest
strong correlation with the low-contrast visual acuity (LCVA) tests (r = 0,7). LCVA tests are
more sensitive to increased intraocular straylight, but not be used to asses level of intraocular
straylight, because they show individual difference between participants.
Keywords: high contrast visual acuity, low contrast visual acuity, intraocular straylight. | en_US |
dc.language.iso | N/A | en_US |
dc.publisher | Latvijas Universitāte | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Fizika | en_US |
dc.title | Zema kontrasta redzes asuma testu pielietojums redzes kvalitātes novērtēšanai | en_US |
dc.title.alternative | Assessment of visual quality with low contrast acuity tests | en_US |
dc.type | info:eu-repo/semantics/masterThesis | en_US |