dc.contributor.advisor | Saknīte, Inga | en_US |
dc.contributor.author | Silapētere, Arita | en_US |
dc.contributor.other | Latvijas Universitāte. Fizikas un matemātikas fakultāte | en_US |
dc.date.accessioned | 2015-03-24T08:43:58Z | |
dc.date.available | 2015-03-24T08:43:58Z | |
dc.date.issued | 2013 | en_US |
dc.identifier.other | 34203 | en_US |
dc.identifier.uri | https://dspace.lu.lv/dspace/handle/7/25691 | |
dc.description.abstract | Darba mērķis ir izveidot ādas hromoforu in vitro maketu un veikt tā optisko īpašību eksperimentālu izpēti ar multispektrālās attēlošanas metodi.
Tika izveidoti 4 maketi, kuru optiskās īpašības ir līdzīgas ādas hromoforu optiskajām īpašībām. Ādas hromoforu – bilirubīna, hemoglobīna un melanīna – maketu absorbcijas kvantitatīvai novērtēšanai kopā tika uzņemti 144 spektrālie attēli. Katras hromoforas maketa darbība tika pārbaudīta ar 6 paraugiem, variējot hromoforu koncentrāciju.
Darba rezultāti parāda, ka sintezēts bilirubīns, eritrocītu masa, nigrozīns un kafija var tikt izmantoti ādas hromoforu in vitro maketos, lai to optiskās īpašības atbilstu bilirubīna, hemoglobīna un melanīna optiskajām īpašībām ādā. Izveidotie maketi var tikt izmantoti multispektrālās attēlošanas iekārtu kalibrēšanai. | en_US |
dc.description.abstract | The aim of this thesis is to create skin chromophore in vitro phantom and to experimentally examine its optical properties with multispectral imaging technique.
In this study, 4 phantoms were created that simulate optical properties of skin chromophores. For quantitative measurements of chromophore – bilirubin, haemoglobin and melanin – phantom absorption, 144 spectral images were obtained. In order to test the developed phantom, 6 samples for each chromophore were made with different concentrations.
The results show that synthesized bilirubin, mass of erythrocytes, nigrosin and coffee can be used in skin chromophore in vitro phantoms to simulate bilirubin, haemoglobin and melanin absorption spectrum. The developed phantoms can be used for multi-spectral imaging apparatus calibration. | en_US |
dc.language.iso | N/A | en_US |
dc.publisher | Latvijas Universitāte | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Fizika | en_US |
dc.title | Ādas hromoforu in vitro kartēšanas maketa izveide un eksperimentāla izpēte | en_US |
dc.title.alternative | Development and experimental study of phantom for mapping of skin chromophores | en_US |
dc.type | info:eu-repo/semantics/bachelorThesis | en_US |