Ekscentriskā fotorefraktometra "PowerRef 3" kalibrēšana

Thumbnail
View/Open
304-65275-Hermane_Zaklina_zh15001.pdf (1.051Mb)
Author
Hermane, Žaklīna
Co-author
Latvijas Universitāte. Fizikas un matemātikas fakultāte
Advisor
Panke, Karola
Date
2018
Metadata
Show full item record
Abstract
Bakalaura darbs ir uzrakstīts latviešu valodā uz 26 lapaspusēm. Tas satur 17 attēlus un 19 atsauces uz literatūras avotiem. Darba mērķis bija noskaidrot ierīces “PowerRef 3”, kas atrodas Latvijas Universitātes Optometijas un redzes zinātnes nodaļā, precizitāti izmantojot relatīvās kalibrēšanas metodi. Papildus ierīces kalibrēšanai tika veikti akomodācijas izmaiņu mērījumi cikloplēģijas iespaidā. Dati tika iegūti izvērtējot dalībnieku labo aci monokulāros apstākļos. Relatīvās kalibrēšanas metodes laikā katrs mērījums tika veikts 10 sekundes. Tika iegūti rezultāti, kas nosaka, ka ierīce “PowerRef 3” ir atbilstoša ierīces rokas grāmatā noteiktajām specifikācijām.
 
Bachelor’s work is written in Latvian on 26 pages. It contains 17 images and 19 references. The aim of the work was to find out appliance “PowerRef 3”, which is in University of Latvia department of Optometry and vision science, precision using relative calibration. In addition to calibration, measurements of the differences of accommodation were made under influence of cycloplegia. Data were obtained observing participants’ right eye in monocular conditions. Every measurement was obtained for 10 seconds in relative calibration. The results of the appliance “PowerRef 3” were obtained, that determines its adequacy of specifications in manual.
 
URI
https://dspace.lu.lv/dspace/handle/7/38901
Collections
  • Bakalaura un maģistra darbi (FMOF) / Bachelor's and Master's theses [2775]

University of Latvia
Contact Us | Send Feedback
Theme by 
@mire NV
 

 

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

Login

Statistics

View Usage Statistics

University of Latvia
Contact Us | Send Feedback
Theme by 
@mire NV