Show simple item record

dc.contributor.advisorKrūmiņa, Guntaen_US
dc.contributor.authorBistere, Aivijaen_US
dc.contributor.otherLatvijas Universitāte. Fizikas un matemātikas fakultāteen_US
dc.date.accessioned2015-03-24T08:01:20Z
dc.date.available2015-03-24T08:01:20Z
dc.date.issued2010en_US
dc.identifier.other17456en_US
dc.identifier.urihttps://dspace.lu.lv/dspace/handle/7/21611
dc.description.abstractMaģistra darbs ir uzrakstīts latviešu valodā uz 60 lpp. Tas satur 36 att., 1 tab., 4 pielikumus. Izmantoti 57 literatūras avoti. Darba mērķis:Novērtēt un salīdzināt klīniskos rezultātus starp metodēm, kur radzenes vāciņš lāzerķirurģijas laikā veidots ar VisuMax femtosekunžu lāzeri(FemtoLASIK metode) un ar mehānisko mikrokeratomu(LASIK metode). Metodika:Pētījumā tika analizēti 84 miopi pacienti(154 acis)-LASIK metodē-59 pacienti,FemtoLASIK-25. Vidējais vecums 29±8 gadi. Pirms operācijas subjektīvās refrakcijas MSE LASIK metodē bija -4,81±2,44D,FemtoLASIK: -5,32±2,38D. Vidējais BSCA pirms LASIK metodes bija 1,1±0,2,FemtoLASIK:1,1±0,1. Nomērītais vidējais IOS pirms LASIK bija 16,2±2,8mmHg, FemtoLASIK:16,7±3,0mmHg. Rezultāti:3mēn. pēc LASIK subjektīvās refrakcijas MSE bija -0,18±0,44D,FemtoLASIK: -0,21±0,51D; refrakcijas prognozējamība ar ±0,50D lielu intervālu pēc LASIK metodes bija 85% gadījumu,FemtoLASIK:90% gadījumu; UCVA 1,0 un labāks pēc LASIK metodes bija 81%,FemtoLASIK:82%. Nomērītais IOS 3 mēn. pēc LASIK metodes bija 11,1±2,2mmHg,FemtoLASIK:10,5±2,2mmHg. Secinājumi: Pētījumā konstatēts, ka klīniskās atradnes, tas ir, refrakcijas stabilitāte un prognozējamība, redzes asuma izmaiņas un noturība, IOS mērījumu izmaiņas, starp LASIK un FemtoLASIK metodēm ir līdzīgas.en_US
dc.description.abstractMaster’s work is written in Latvian. It consists of 60 p. It contains 36 fig., 1 table, 4 appendice. 57 literature sources are used in master’s work. Purpose:To assess and to compare clinical outcomes between VisuMax femtosecond laser(FemtoLASIK method) and the mechanical microkeratome(LASIK method) for creating corneal flaps during LASIK. Methods: The study involved a total of 154 eyes of 84 myopic patients, with 59 patients comprising the LASIK and 25 patients comprising the FemtoLASIK. Average age 29±8 years. Preoperative subjective refractions MSE before the LASIK was -4,81±2,44D,the FemtoLASIK: -5,32±2,38D. Subjective average BCVA before the LASIK was 1,1±0,2,the FemtoLASIK:1,1±0,1. Measured mean IOP before the LASIK was 16,2±2,8mmHg, FemtoLASIK:16,7±3,0mmHg. Results:At 3 months after the LASIK, subjective refractions the MSE was -0,18±0,44D, after the FemtoLASIK: -0,21±0,51D; the predictability of refraction within ±0,50D interval after the LASIK was 85%, the FemtoLASIK – 90%; UCVA 1,0 or better after the LASIK was 81%, the FemtoLASIK – 82%. Measured mean IOP at 3 months after the LASIK was 11,1±2,2mmHg, the FemtoLASIK – 10,5±2,2mmHg. Conclusions:3 months after laser surgery clinical outcomes(stability and predictability of refraction, efficacy and safety of visual acuity, IOP measurement changes) in the LASIK and FemtoLASIK method were similar.en_US
dc.language.isoN/Aen_US
dc.publisherLatvijas Universitāteen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectFizikaen_US
dc.titleKlīnisko atradņu salīdzinājums FemtoLASIK un LASIK metodēsen_US
dc.title.alternativeComparison of clinical findings between FemtoLASIK and LASIK methodsen_US
dc.typeinfo:eu-repo/semantics/masterThesisen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record